Specification Sheet: Copy Number Variation (CNV)
Specifications for Oxford Gene Technology (OGT) microarray service for CNV studies.
| Measurable | Enzymatic CNV | ULS CNV |
| 360° QC | DNA QC on sample arrival QC of sample labelling efficiency LIMS sample tracking |
|
| Microarray platform | Agilent SurePrint™ HD and G3 CGH microarray |
|
| Species covered | Catalogue: Human, mouse, rat, chicken Bespoke: Designed using eArray or the Oligome™; our library of >24 million high resolution CNV probes spanning the entire genome |
|
| Array density | 1x244k, 2x105k , 4x44k, 8x15k G3: 1x1M, 2x400k, 4x180k, 8x60k |
1x244k, 2x105k , 4x44k, 8x15k G3: 1x1M, 2x400k, 4x180k, 8x60k |
| Experimental design consultancy | Avaliable on request |
|
| Sample preparation consultancy | Available on request |
|
| Starting sample | Genomic DNA from blood, cells, or frozen tissues | FFPE and genomic DNA from blood, cells, or frozen tissues |
| Starting sample requirement | 260/280 >1.8 260/230 >1.8 1x: 0.5–3.0 μg 2x: 0.5–1.5 μg 4x: 0.5–1.5 μg 8x: 0.2–0.5 μg |
260/280 >1.8 260/230 >1.8 1x: 2.0 μg 2x: 1.0 μg 4x: 0.5 μg 8x: 0.25 μg |
| Sample QC method | NanoDrop™ 8000 spectrophotometer and gel electrophoresis | NanoDrop 8000 spectrophotometer and Agilent Bioanalyzer 2100 |
| Labelling method | Enzymatic labelling | Kreatech ULS |
| Slide printing | Agilent SurePrint technology |
|
| Replicate no. of probes | Tiling array: Variable numbers of multiple single probes per CNV region |
|
| Tm equalised | Yes |
|
| Database version | Genome build: hg18 |
|
| Custom sequences | Can be added |
|
| Custom design by OGT | Available on request |
|
| Single/dual colour | Both |
|
| Dynamic range | 5 logs |
|
| Data analysis | Tailored to customer requirements (includes feature extraction, QC report, CytoSure™ analysis) |
|
| Data format | Tailored to customer requirements TIFF images, XML files, TXT files (raw data), customer report, relevant data analysis files (e.g. CytoSure), QC report |
|
FFPE: Formalin-fixed, paraffin-embedded; LIMS: laboratory information management system; QC: quality control; ULS: Universal Linkage System.
Download a copy of this specification sheet.